Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
1.
Arch. med. res ; 30(1): 49-54, ene.-feb. 1999. tab, graf
Article in English | LILACS | ID: lil-256620

ABSTRACT

Background. Technetium-99m-mercaptoacetyltriglycine (99-mTc-MAG3) is a radiopharmaceutical for tubular function and can be prepared with 99-mtechnetium and the ligand Bz-MAG3 (Instituto Nacional de Investigaciones Nucleares, Mexico City). No radiopharmacokinetic parameters have been found for the healty adult Mexican population with 99mTc-MAG3, prepared with the nationally produced or imported Bz-MAG3 kit. Methods. The radiopharmacokinetic parametrs and the clearance of 99mTc-Mag3 in seven healthy Mexican volunteers were determined by the single-and multi-sample methods. Computer programs were used for the calculations. Results. Using several plasma samples from 0.43 min and the BIEXP program, it was show that 99mTc-MAG3 follows a two-compartment model of distribution, with an apparent volumen in the central compartment Vdcc = 6.7 + 1.0 1, T½Ó = 0.07 + 0.02 h-1, T½ ß = 0.49 + 0.15 h-1, mean residence time MRT = 0.60 + 0.17 h and clearance = 208 57 (ml/min)/1.73 m². In comparison, the clearance value with a single sample drawn 43 min post-injection and calculated with Tauxe's formula was 193 ñ 59 (ml/min)/m². Conclusions. The 15 ml difference between the two methods is neither statistically different (p= 0.11) nor important for routine clinical studies. The single-sample method is recommendad because it is reliable and can be done at the same time that dynamic renal scan is aquiered. Estimated absorbed radiation dose was calvulated for several organs


Subject(s)
Humans , Male , Female , Middle Aged , Radiopharmaceuticals , Technetium Tc 99m Mertiatide/pharmacokinetics , Radiation Dosage , Radiometry , Technetium Tc 99m Mertiatide/blood , Kidney Function Tests , Tissue Distribution
2.
Rev. invest. clín ; 49(5): 373-7, sept.-oct. 1997. tab, ilus
Article in Spanish | LILACS | ID: lil-219691

ABSTRACT

Objetivo. Comparar la calidad de las imágenes de gammagrafía ósea obtenidas con un radiofármaco nuevo, el 99mTc-ABP, con aquéllas obtenidas con el 99mTc-MDP. Material y métodos. Fue un estudio comparativo en un mismo sujeto. Se estudiaron 9 voluntarios sanos (5 mujeres y 4 hombres) de 23 a 39 años de edad. A todos se les inyectaron 740 MBq de los radiofármacos Tc-ABP y Tc-MDP con un intervalo de 72 horas entre uno y otro. Dos horas después de cada inyección se les realizó un gammagrama óseo de cuerpo entero con una cámara de centello MultiSpect 2 y se determinaron los parámetros radiofarmacocinéticos. Tres médicos nucleares evaluaron por separado la calidad de las imágenes mediante el trazado de regiones de interés (RDI) sobre vértebras, costillas, esternón, fémur, articulaciones y cráneo. Se obtuvieron relaciones hueso/músculo con RDI sobre diferentes huesos. Los resultados se compararon etadísticamente con las pruebas de kappa y de Wilcoxon. Resultados. La concordancia sobre la calidad de las imágenes de los dos radiofármacos por los tres observadores fue moderada (kappa 0.4). La relación fémur/músculo mostró una distribución normal y no manifestó diferencias significativas entre radiofármacos. Conclusiones. La calidad de las imágenes con ambas preparaciones fue similar. Recomendamos utilizar al 99mTc-ABP en la gammagrafía ósea debido a la menor exposición a radiación del paciente


Subject(s)
Humans , Male , Female , Adult , Alendronate , Bone and Bones , Organotechnetium Compounds , Organotechnetium Compounds/pharmacokinetics , Technetium Tc 99m Medronate , Technetium Tc 99m Medronate/pharmacokinetics
3.
Arch. med. res ; 27(4): 481-3, 1996. ilus
Article in English | LILACS | ID: lil-200350

ABSTRACT

The purpose of this paper is to report the preparation of a new technetium-99m-radiopharmaceutical for bone scanning. The chelating agent for99mTc is a new bisphosphonate, alendronate, 4-amino-1-hydroxy-butylidene-1,1-bisphosphonate (ABP) used as a treatment for osteoporosis. ABP, because of its amino group, seems to be better suited to form a strong and stable complex with technetium-99m and therefore might be better than 99mTc-etidronate (HEDP) or 99mTc-medronate (MDP) for bone scanning. A sterile dry kit containing APB, a reducing agent and a stabilizer was prepared. The parameters studied were molar concentrations, pH, shelf life, labeling efficiency and radiochemical purity. the oven dried sterile kit was formulated with 5 mg ABP, 0.25 mg stannous fluoride and 0.025 mg gentisic acid at pH2.5-3.5. The labeling efficiency with 20 - 1500 MBq of pertechnetate (99mTcO4-) was over 95 percent at room temperature and was stable for 5 h. Technetium-99m-alendronate was tested in two rabbits and it proved to be a promising new radiopharmaceutical for bone scanning. Work is underway to study underway to study 99m-Tc-ABP biodistribution in a statistically significant number of laboratory animals and, later on, to determine radiopharmacokinetic parameters in normal volunteers


Subject(s)
Bone and Bones , Decalcification, Pathologic/physiopathology , Diphosphonates , Microscopy, Electron, Scanning/methods , Osteoporosis/therapy , Radiochemistry/methods , Technetium Compounds
4.
Rev. invest. clín ; 47(2): 133-8, mar.-abr. 1995. ilus, tab
Article in Spanish | LILACS | ID: lil-158865

ABSTRACT

Antecedentes. En la actualidad, de los departamentos de medicina nuclear cuentan con cámaras de centelleo para gamagrafía computarizada. Para el radiorrenograma se adquieren 90 imágenes de 16 segundos cada una, se integran en una sola y sobre ella se trazan regiones de interés (RDI) dibujado el contorno de los riñones y de la vejiga, por medio de una palanca móvil ("joy stick"). El programa utliza la radiactividad de cada RDI para generar curvas de actividad/tiempo, y calcular el tiempo de máxima actividad renal (Tmax) y el tiempo que tarde el riñón en eliminar la mitad de esta radiactividad T½). El dibujo del contorno de órgano, al trazar las RDI, es el único paso en que interviene directamente el operador por lo que cabe la posibilidad de que los resultados dependan de su habilidad y experiencia, y por ende, que hubiera diferencias interoperadores que repercutieran en la interpretación clínica de los gamagramas. Objetivo. Establecer la variabilidad interoperadores de cuatro personas experimentadas en el trazado de RDI en imágenes renales. Material y métodos. Los cuatro operadores trazaron las RDI para obtener la Tmax Y T½ de 38 riñones de 20 pacientes (dos trasplantados). Se calculó el CV interoperadores de Tmax y T½ de los 38 riñones. Resultados. Globalmente hubo mayor variabilidad interobservadores en T½ que en Tmax. Cuatro riñones mostraron pequeñas diferencias interoperadores en Tmax y/o T½ pero suficientes para que discreparan sus clasificaciones de normal/retardado. La separación de los datos en tres grupos (T = Tmax y T½ normales; 2 = Tmax normal y T½ retardada; 3 = ambas retardadas) mostró que había diferencias intergrupos significativas en el CV interobservadores de la Tmax (Kruskal-Wallis p = 0.032) que obedecían a que la variabilidad fue mayor en el grupo 2 (6 de 11 riñones con CV >4 por ciento) que en los grupos 1 y 3 (ninguno con CV >4 por ciento). Conclusiones. 1. Las discrepancias interoperadores tuvieron repercusión sólo en algunos casos en que los parámetros estaban ligeramente retardados (8-9 min en Tmax, 15-20 min en T½). 2. No tenermos una explicación de por qué hubo mayor variabilidad interoperadores en Tmax de los riñones del grupo 2 (Tmax normal con T½ retardada). 3. Creemos que un estudio de la variabilidad interoperador de estas mismas cuatro personas puede aclarar algunas de las observaciones de este estudio


Subject(s)
Scintillation Counting/instrumentation , Scintillation Counting/methods , Scintillation Counting , Kidney , Tomography, Emission-Computed/methods , Tomography, Emission-Computed
SELECTION OF CITATIONS
SEARCH DETAIL